Pi2R iX Solar Geyser Controller

R5 750.00

Specifications

Memory:

  • 48 Hour minutely PV power data Graph
  • 48 Hour minutely temperature data Graph

Backup power:

  • Lithium chargeable battery

Full charge time:

  • 2 Hours
  • Backup power to see temperature while power-out
  • Backup power should last at least 4 hours

Communications:

  • RS485 non-isolated
  • BAUD 115200,8n1
  • Wire length up to 250meter
  • CRC

Error detection Thermostat:

  • ±0.5º Celsius accuracy
  • Wire length up to 10meter
  • CRC Error detection
  • Error on Temp > 85º Celsius

5 in stock (can be backordered)

wws Monique / Pre-sale Questions Need Help? Contact Us via WhatsApp
Pi2R iX Solar Geyser Controller
Pi2R iX Solar Geyser Controller R5 750.00
Only 5 items left in stock!
Guaranteed Safe Checkout

rapid ssl

Description:

The iX has two different operating modes, one with a display and one without.

Connection without a Display

In this mode temperature can only be set with the existing AC thermostat. No extra settings
possible.

In this mode priority is always given to grid power (AC). This enables the unit to be manually
forced to use grid when DC power is available but not sufficient. Otherwise when DC is only at
10% (for example) then the water cannot be heated up quickly if the user so required.

Thus to automate functionality, AC needs to be switched through a standard geyser timer. This
timer will enable AC at set times to ensure acceptable water. The timer also ensures that DC is used
during sunlight hours as it removes AC during daytime.

Contrary to expectation AC is not always used during these times. AC will be available but not
used when the geyser is warm enough

Connection with a Display

In this mode all programming is done via the Display and the existing thermostat is turned up to
maximum temperature to avoid intervening with user settings while still providing a safety backup.

Override

The geyser can be manually overridden in order to heat up once-off. Overrides will not repeat
automatically.

Timers

Two independent timers can be set when AC may be used.
Contrary to expectation AC is not always used during these times.
AC will not be used when:

  • Water is warm enough
  • Loadshedding

Temperatures

Two independent temperatures can be set. One for AC and one for DC/PV.
When the Temperature reaches the AC set-point then the unit will switch to PV power if available
(even during Timer operation).
It is therefore important to set the AC temperature lower than the DC temperature, otherwise power
saving will be hindered.


City of Capetown

Both Pi2R Micro Solar Geyser Controller and iX can be used under Capetown regulations, both are NRCS approved as
required.

Additional information

Weight 1 kg
Dimensions 15 × 20 × 6 cm